Show simple item record

dc.contributor.authorMulukutla, Rahulen_US
dc.date.accessioned2007-08-23T01:56:24Z
dc.date.available2007-08-23T01:56:24Z
dc.date.issued2007-08-23T01:56:24Z
dc.date.submittedDecember 2005en_US
dc.identifier.otherDISS-1162en_US
dc.identifier.urihttp://hdl.handle.net/10106/273
dc.description.abstractThe focus of this thesis is the development and investigation related to the newest prototype version of the Human Performance MultiMeter (HPMM). Version 4 is a technologically advanced, compact, portable and self-contained unit that is the result of an on-going effort in human performance measurement covering a 25 year history at the Human Performance Institute involving the conception, development, and evaluation of over four hundred different measures. Such measurements are applicable in areas ranging from medical diagnosis and rehabilitation to ergonomics and athletic proficiency. The work included verification of the functionality of a new hardware platform, modification of previously developed test procedures and software algorithms for the new hardware, and new development for selected aspects of the system. Steadiness measurement has been expanded to include components based on two axes of rotational rate and the formulation of a four degree of freedom composite steadiness measure. Five generic tests incorporated in this version of the HPMM were used in an experimental study with 20 healthy adult volunteers to evaluate reliability and validity. Selected performance capacities of specific body subsystems (isometric grip strength, visual-hand response speed, index finger tapping speed, upper extremity neuromotor channel capacity, and hand-arm steadiness) were measured in a test-retest design: . Test-retest reliability was found to be very good (r > 0.75) for most measures. Results were compared to those from HPMM v3.0 and to results from pre-established, validated data acquired over the years from laboratory based instruments. Good agreement was noted and expected patterns supporting validity were observed.en_US
dc.description.sponsorshipKondraske, Georgeen_US
dc.language.isoENen_US
dc.publisherElectrical Engineeringen_US
dc.titleHuman Performance Multimeter: Investigation Of The Fourth Generation Prototypeen_US
dc.typeM.S.E.E.en_US
dc.contributor.committeeChairKondraske, Georgeen_US
dc.degree.departmentElectrical Engineeringen_US
dc.degree.disciplineElectrical Engineeringen_US
dc.degree.grantorUniversity of Texas at Arlingtonen_US
dc.degree.levelmastersen_US
dc.degree.nameM.S.E.E.en_US
dc.identifier.externalLinkhttps://www.uta.edu/ra/real/editprofile.php?onlyview=1&pid=219
dc.identifier.externalLinkDescriptionLink to Research Profiles


Files in this item

Thumbnail


This item appears in the following Collection(s)

Show simple item record